Electrical

High Voltage Cables

Specifications: Cables as per IEC / VDE / IEEE or any other international specifications
Grades: 66 kV to 220 kV
Cross Sectional Area: 95 sq. mm. to 2000 sq. mm.
Conductor: Copper / Aluminium
Insulation: Super clean XLPE
Armour: Aluminium wire
Sheathing: HDPE with extruded layer of semi-conducting material

Medium Voltage Cables

Specifications: Cables as per BIS / BS / IEC or any other international specifications
Grades: 3.8 kV to 33 kV
Core: Single & three core
Cross Sectional Area: 35 sq. mm. to 1000 sq. mm.
Conductor: Aluminium / Copper
Insulation: XLPE
Armour: Aluminium / Galvanized Steel (Wire/Tape)
Sheathing: PVC / PE / LSF

Low Voltage Cables

Specifications: Cables as per BIS / BS / IEC or any other international specifications
Grades: 600 / 1000 V, 1.9 / 3.3kV
Core: Single to 100.
Cross Sectional Area: 1.5 sq. mm. to 1000 sq. mm.
Conductor: Aluminium / Copper
Armour:: Aluminium / Galvanized Steel
Sheathing: PVC / PE / LSF

Instrumentation Cables

Specifications: Cables as per BS 5308 Part-1/Part-2, BS EN 50288-7 or any international standard.
Type: Pair / Triad / Quads
No of Pair/Triad/Quads: Up to 50 pairs/triads/Quads
Size: 0.5 sq.mm to 4 sq.mm.
Conductor: Plain / tinned copper
Insulation: XLPE / PE / PVC
Shielding: Al. Mylar foil screen / Braided screen
Armour: Galvanized steel wire / tape / braid / or unarmoured
Sheath : PVC / LSF.

Wiring Cables

Specifications: Wires as per BS 6004/ BS EN 50525-2-31 / IEC 60227 or other international specifications
Core: Single Core
Cross Sectional Area: 0.5 sq. mm. to 6.0 Sq.mm
Conductor: Copper Stranded (Class 2) or flexible (Class 5)
Insulation: PVC

PVC Flexible Cables

Specifications: Cables as per BS 6004 / BS 6500 / BS 7919 / BS EN 50525-2-11 / IEC 60227
Core: Single to 5
Cross Sectional Area: 0.5 sq. mm. to 4 sq. mm.
Conductor: Copper Flexible (Class 5)
Insulation: PVC
Sheathing: PVC

LSF /LSZH Cables

Specifications: Cables as per BS 7211 / BS EN 50525-3-41 / BS 6724 / BS 7835
Core: Single to 100
Cross Sectional Area: 1.5 sq. mm. to 1000 sq. mm.
Conductor: Aluminium / Copper
Insulation: XLPE
Armour: Aluminium / Galvanized Steel
Sheathing: LSF / LSZH, Zero Halogen – no corrosive gas emission

Fire Resistant Cables

Specifications: Cables as per BS 7846 / BS 6387 CWZ / IEC 60502-1 / IEC 60331
Core: Single to 100
Cross Sectional Area: 1.5 Sq.mm – to 1000 sq.mm
Conductor: Copper / Aluminium
Flame Barrier : Glass Mica Tape
Insulation: XLPE
Armour: Aluminium / Galvanized Steel.
Sheathing: LSF / LSZH, Zero Halogen – no corrosive gas emission.

Speciality Cables